A reference from Harbauer Berlin GmbH. More references from Harbauer Berlin GmbH

Groundwater purification of VOCs

"Alte Königsheide Süd" site in Berlin-Treptow

Treated media: Soil, Groundwater, Air

Flow rate: 240 (m3/h)

Substances: VOC

Processes: Desorption, UV oxidation

Commissioning: 2016

KF Company: Harbauer Berlin GmbH

723408 Alte Koenigsheide Sued

Most of the vinyl chloride is converted into the gas phase in the first column. The polluted air is then passed through a droplet separator into a UV oxidation reactor, in which the vinyl chloride is oxidized to carbon dioxide, water, and hydrochloric acid.

The purified exhaust air is admixed to the higher desorption air stream of the second column.

The second desorption stage is followed by exhaust air treatment by means of two active carbon air filters connected in parallel. These are ideally suited for the preparation of cis-dichloroethane and trichloroethene.

The purified water is finally delivered to the Kannegraben and thus to the pre-flood.

Download this reference as PDF
Contact person at Harbauer Berlin GmbH

Do you have any questions about our services. Then we look forward to your contact request!

Axel Bernstorff
Manager